Rectifier and Battery Power Systems
LORAIN ® A8CAB/BD Power System
Note: the Ordering Form is in MS Excel format. It may be filled in online, and then printed by clicking on the printer icon in the browser tool bar. The form may then be faxed to API at 416-281-6904. If you cannot view this form contact us at 416-281-6902.

Rectifier and Battery Power Systems

The LORAIN ® A8CAB/BD power system is comprised of a modular lightweight -48 VDC, 2-8 amp rectifier cabinet with optional battery cabinets. Systems can be specified in a variety of configurations to suit your specific power requirements.

Lorain ® A8CAB/BD Power System

The rectifier cabinet is arranged to accept up to four 2 amp rectifier modules that supply 48 VDC load current while float charging a standby battery. If commercial power fails, the battery immediately supplies load current. Six GMT fuse positions are provided for individual load protection. Local and remote indicators provide status for AC, rectifiers, load and battery. The cabinet is equipped with an IEC 320 socket arranged for 120/220 VAC 50/60 HZ commercial power.

Battery cabinets can be specified in 7 or 12 amp hour capacities. Multiple or larger batteries can be provided where longer reserve times are required. Each battery is protected by an internal fuse and a low voltage disconnect is included to protect battery and load.

Lorain ® A8CAB/BD Battery Cabinet

Units are designed to mount adjacent to the equipment being powered, and connectorized cables can be supplied to simplify on-site installation.

Features & Benefits

  • Modular Design—easy to configure, maintain and expand
  • Compact, Lightweight Cabinets—permits one person installation in limited space
  • Temperature Hardened—dependable operation in harsh environments
  • Low Voltage Disconnect—provides complete load and battery protection
  • Wall or Rack Mounting—adaptable to all types of site configurations
  • Optional Batteries—covers a wide range of loads and reserve times
  • Local and Remote Alarms—continuously monitors complete system status

Application

The A8CAB power system is comprised of a modular lightweight -48VDC, 2-8 Amp rectifier cabinet with optional battery cabinets. Systems can be specified in a variety of configurations to suit your specific power requirements. The rectifier cabinet is arranged to accept up to (4) 2-amp rectifier modules that supply 48 VDC load current while float charging a standby battery. The cabinet is equipped with an IEC 320 socket arranged for 120/220 VAC, 50/60 Hz commercial power.

Battery cabinets can be specified in 7 or 12 amp hour capacities. Multiple or larger batteries can be provided where longer reserve times are required. Units are designed to mount adjacent to the equipment being powered and connectorized cables can be supplied to simplify on-site installation.

The A8CAB is designed to supply primary or backup DC power to communications equipment installed in remote cabinets or on customer's premises. Specific applications include: microwave PBX, key systems, multiplexers, PCS equipment, xDSL products, Routers, FITL electronics and alarm or security circuits.

Rectifier and Cabinet Specifications

Input
Voltage: 120/220 VAC, single phase
Range:90-132/180-264 VAC
Frequency: 50/60 Hz (47-63 Hz)
Connection: IEC 320 receptacle detachable cordset, 6' (1.83 m)

Output
Voltage: 52-58 VDC (set at 54.8 V)
Regulation: ± 1% over line and load variations
Voltage/Drift: ± 0.25% max. over 8 hours at constant line and load
Filtering: Less than 30 mV rms

System
Configuration
Load
Current
Operating
Temperatures
1
Rectifier
1.5 amp -40 to +65 °C
(-40 to +149 °F)
2.0 amps -40 +50 to °C
(-40 to +122 °F)
4
Rectifiers
6.0 amps -40 + 65 to °C
(-40 to +149 °F)
8.0 amps -40 +50 to °C
(-40 to +122 °F)

Note: Above ratings are based on convection cooling. With 210 CFM (5.95 cu.m/min) air flow, rectifiers will deliver 2 amps per card at +65°C (+149° F).

Protection
AC Input: 5 amp fuse per rectifier
DC Output: (6) 0-5 amp GMT fuses
Battery: 10 amp GMT fuse
Rectifier: Thermal current limit
High voltage shutdown: 59 VDC
Audible Noise: Less than 45 dBA measured 5'

Alarm and Controls
Visual: AC OK (green), Rectifier Fail (Red),
Battery Fail (Red), Load Fuse Fail (Red)
Remote Alarms: AC Fail; Rectifier Fail; Battery Alarm; Load Fuse Alarm
Remote alarms are "C" type relay contacts. LVA preset at 46 V, switch selectable 43-47 V LV disconnect at 42 V, reconnect at 47 V. Internal LVD maintenance bypass switch. Test points to measure rectifier voltage.

Batteries
Capacity: @20 Hr rate and 25° C (77° F)
LO6: 12 AH
LO7: 7 AH
Type: Sealed VRLA
Fusing: 10 amp TPA-style GMT
Flammability: UL94 VO flame retardant case
Shelf Life: 6 months
Predicted Life: 3-5 years @ +25°C (77° F), 54.8-55.4V

Cabinet Height Width Depth Weight
Rectifier 7.00"
177.80 mm
14.00"
355.60 mm
6.00"
152.40 mm
7.00 lbs.
3.2 Kgs
7 AH
Battery
7.00"
177.80 mm
14.00"
355.60 mm
6.00"
152.40 mm
34.5 lbs.
15.65 Kgs
12 AH
Battery
9.75"
247.65 mm
14.00"
355.60 mm
6.00"
152.40 mm
47.50 lbs.
21.55 Kgs

All cabinets are front access only and are arranged for wall mounting. Optional 19" and 23" (58.42 cm) rack mounting kit available.
Finish: Textured off-white

Environmental
Operating Temperature: -40° C to +65° C (-40° F to +149° F)
Storage Temperature: -40° C to +85° C (-40° F to +185° F)
Humidity: 0-95%, noncondensing
Altitude: Sea level to 10,000' (3048 M)
Ventilation: Bottom to top convection, optional fan cooling
Audible Noise: Less than 45 dBA measured 5' (1.52 M) from any surface
EMI: FCC part 15 subpart B class A
Surge Protection: ANSI/IEEE C62.41 1980 Category B
Seismic: Designed for NEBS Zone 4

Safety Compliance
CSA Certification: CSA 22.2 Number 950
UL 1950
CE(pending)

Additional Information
For additional specifications, engineering and installation information, specify 5882-470-00 instruction manual (section CF5399).

A full complement of accessory hardware is available, please contact us for information.

Battery Information

Battery Information Graph - Discharge Time x Discharge Current
Load Current (Amps) 0.5 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Battery Type Discharge Time (Hours)
List 07 7 AH 11.8 6 3.7 2.7 1.7 1.2 0.9 0.8 0.6 0.5
List 06 12 AH 21.4 11.3 7.2 5.1 2.9 2.4 1.8 1.4 1.2 1.0
2 x List 06 2 x 12 AH   21.4 15.7 11.3 7.2 5.1 3.7 2.9 2.5 2.4

Note: All data shown above is typical. Actual results will vary depending upon battery and environmental conditions.

Typical Configuration

A8CAB/BD Rectifier Cabinet
A8CAB/BD Rectifier Cabinet

Ordering Information

The following ordering guide lists components and standard system configurations that cover a wide range of load and battery backup requirements. For special configurations, cables, line cords or batteries please consult us.

A8CAB Power System Ordering Guide

    Spec. Number
Step 1. Select Basic Power System Cabinet:  
  Wall mount power system cabinet e/w line cord, alarm card, LVD, (6) load fuses and space for up to (4) rectifier cards…… 58824700010
Step 2. Forced Air Ventilation Required?  
  Rectifiers are rated for 2 Amps up to 50C, 1.5 Amps from 50C to 65C. If full 2 Amps is required up to 65C, specify fan assembly…… 58824700045
Step 3. Spare Alarm/Control Card Required?  
  Alarm and control card e/w LVD (select (1) per power cabinet)…… 58824700003
Step 4. Output Current (Load) Requirement?  
  A2F50 Rectifier………Select (1) for each 2 Amps load 58824700002
  If redundant rectifier is required?…………...Specify (1)
  Are spare rectifiers required?……………...Specify Qty
  Total rectifiers required?…..(Not to exceed 4 + spares)
Step 5. Batteries Required?  
  No…...Go to Step 6.  
  Yes….Specify to meet required reserve time per Table 1 below  
  Wall mount battery cabinet e/w 12 Amp hour battery…… 58824700006
  Wall mount battery cabinet e/w 7 Amp hour battery…… 58824700007
  If quantity of battery cabinets is (2), specify (1) Y adapter cable…… 58824700047
  If battery is to be used in high temperature environment, specify (1) temperature compensation module per battery cabinet…… 58824700046
Table 1 Battery Reserve Times
LOAD    CURRENT    (AMPS) 0.5 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0
BATTERY TYPE DISCHARGE TIME (HOURS)
LIST 07 7 AH 11.8 6 3.7 2.7 1.7 1.2 0.9 0.8 0.6 0.5
LIST 06 12 AH 21.4 11.3 7.2 5.1 2.9 2.4 1.8 1.4 1.2 1.0
(2) LIST 06 (2) 12 AH   21.4 15.7 11.3 7.2 5.1 3.7 2.9 2.5 2.4
Step 6. Rack Mounting Kit Required?  
  Above equipment is arranged for wall mounting. If 19" (48.26cm) or 23" (58.42cm) mounting is required, specify (1) rack mount kit per power system cabinet and/or battery cabinet…… 58824700042
Step 7. Accessories:  
  Replacement 12 AH, 48V battery …… 58824700040
  Replacement 7 AH, 48V battery …… 58824700041
  Line cord, 6' (1.83m) NEMA L5-15 twist lock …… 58824700044